GE Challenger - Specification

Power Supply

Input Voltage16-18 Volts AC (space for 7AH battery allocated)
TestingDynamic battery testing
Operating Current150mA maximum (no peripheral devices fitted)
Aux. Power O/P700mA maximum (for detectors etc)

Operating Capacities & Connections

Users65535
Users with PIN Codes65535
Users with Names200 (16 characters)
Alarm Groups128
Alarm Systems/Areas16 (controllable from multiple Arming Stations)
Access Control Doors64 (48 intelligent, 16 standard)
Door Groups128
Lift Groups64
Alarm Inputs16 (expandable to 256 using Data Gathering Panels)
OutputsExpandable to 255 with relay cards.
Siren Drivers2 (8 Ohm monitored siren speaker)
Strobe1
Time Zones24 (each made up of 4 sub-zones)
Time365 day real time clock (with battery back-up)
Holiday/Special Days24
History Alarm Events100 (expandable to 1000)
History Access Control100 (expandable to 1000)
Maximum DGP Connections15 – less if each or any DGP is fully expanded to 32 inputs (12 of which can be Door/Lift Controllers)
Maximum RAS Connections16
Operating Temperature0 - + 70 Degrees

Communications

Max. Distance to Remote LAN Devices1.5kms
Specified Cable for Challenger & Access Controller LANBelden 8723 or equiv
LAN MonitoringContinuous monitoring of Off-Line status of all devices on LAN
AddressingAll remote devices individually addressed via dip switches
ModemStandard on Challenger (auto dialler testing), built-in communicator & V21 Modem
Reporting FormatsMultiple, including Contact ID, Extended High Speed, Serial STU, Dialler/Direct Line and more
Board Size‘C’ board size